Aluminum aging furnace, aluminum aging furnace vertical, vertical aluminum aging furnace for aluminum alloy hardening (solid solution processing), its structure has a hot air circulation passage, and take two-zone temperature control, so tha
parameter name |
Unit |
Model |
||||||
RCL-45-6 |
RCL-50-6 |
RCL-55-6 |
RCL-60-6 |
RCL-70-6 |
RCL-85-6 |
|||
Rated Power |
KW |
45 |
50 |
55 |
60 |
70 |
85 |
|
Rated Voltage |
V |
3Phase/380V |
3Phase/380V |
3Phase/380V |
3Phase/380V |
3Phase/380V |
3Phase/380V |
|
Highest temperature |
℃ |
650 |
650 |
650 |
650 |
650 |
650 |
|
Operating temperature |
℃ |
650 |
650 |
650 |
650 |
650 |
650 |
|
Number of district heating |
Area |
1 |
2 |
2 |
2 |
2 |
2 |
|
Work size |
Long |
mm |
1200 |
1500 |
1800 |
2000 |
2000 |
2200/2000 |
Width |
mm |
600 |
600 |
800 |
800 |
800 |
1000 |
|
High |
mm |
1200 |
1600 |
1000 |
1200 |
1600 |
1350 |
|
Air furnace heating time |
h |
≤1.5 |
≤1.5 |
≤1.5 |
≤1.5 |
≤1.5 |
≤1.5 |
|
Element connection |
Y |
YY |
YY |
YY |
YY |
YY |
YY |
|
Air furnace power loss |
KW |
≤4 |
≤4 |
≤5.5 |
≤5.5 |
≤6 |
≤6 |
|
Temperature control accuracy |
℃ |
±1 |
±1 |
±1 |
±1 |
±1 |
±1 |
|
Temperature uniformity |
℃ |
±5 |
±5 |
±5 |
±5 |
±5 |
±5 |
|
Dimensions |
Diameter |
mm |
~1400 |
~1400 |
~1400 |
~1400 |
~1400 |
~1400 |
Depth |
mm |
~1950 |
~1950 |
~1950 |
~1950 |
~1950 |
~1950 |
|
The maximum loading capacity |
Kg |
300 |
400 |
500 |
600 |
800 |
900 |
|
Complete Weight |
Kg |
6.0T |
6.5 |
6.8 |
7.5 |
8.0 |
8.0 |
More vertical aluminum aging furnace:http://www.industrial-furnace.com/industrialfurnaces/Heat_Treatment_Furnace/aluminum_alloy_furnace.html